How to Fix 061-354 to 061-393 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

061-354 to 357, 061-362 to 365, 061-366 to 369, 061-370 to 373, 061-390 to 393 LPH Communications Fault RAP

061-354 ASIC register error in IBY initial DL check. It may be an error in the yellow LPH (ASIC or memory). It may also be an ASIC malfunction due to poor power supply or a communication error due to poor connection with the ESS.
061-355 ASIC register error in IBY initial DL check. It may be an error in the magenta LPH (ASIC or memory). It may also be an ASIC malfunction due to poor power supply or a communication error due to poor connection with the ESS.
061-356 ASIC register error in IBY initial DL check. It may be an error in the cyan LPH (ASIC or memory). It may also be an ASIC malfunction due to poor power supply or a communication error due to poor connection with the ESS.
061-357 ASIC register error in IBY initial DL check. It may be an error in the black LPH (ASIC or memory). It may also be an ASIC malfunction due to poor power supply or a communication error due to poor connection with the ESS.
061-362 Communication error between ESS and yellow LPH (data read error from LPH). It may occur due to external noise, poor connection of FFC, poor power supply, etc.
061-363 Communication error between ESS and magenta LPH (data read error from LPH). It may occur due to external noise, poor connection of FFC, poor power supply, etc.
061-364 Communication error between ESS and cyan LPH (data read error from LPH). It may occur due to external noise, poor connection of FFC, poor power supply, etc.
061-365 Communication error between ESS and black LPH (data read error from LPH). It may occur due to external noise, poor connection of FFC, poor power supply, etc.
061-366 Communication error between ESS and yellow LPH (data write error to LPH). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-367 Communication error between ESS and magenta LPH (data write error to LPH). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-368 Communication error between ESS and cyan LPH (data write error to LPH). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-369 Communication error between ESS and black LPH (data write error to LPH). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-370 Communication error between ESS and yellow LPH (error in the communication IC or cable). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-371 Communication error between ESS and magenta LPH (error in the communication IC or cable). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-372 Communication error between ESS and cyan LPH (error in the communication IC or cable). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-373 Communication error between ESS and black LPH (error in the communication IC or cable). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.
061-390 Large pixel count error between the video output and yellow LPH. Image abnormality may occur.
061-391 Large pixel count error between the video output and magenta LPH. Image abnormality may occur.
061-392 Large pixel count error between the video output and cyan LPH. Image abnormality may occur.
061-393 Large pixel count error between the video output and black LPH. Image abnormality may occur.

Procedure

Perform the 060-341 to 060-356 LPH Fault RAP.

**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner's property.**

You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.

Toner Chip (For North America and West Europe Region):

106R03741 106R03744 106R03743 106R03742
106R03757 106R03760 106R03759 106R03758
106R03737 106R03740 106R03739 106R03738

Toner Chip (For South America and East Europe Region):

106R03749 106R03752 106R03751 106R03750
106R03745 106R03748 106R03747 106R03746
106R03765 106R03768 106R03767 106R03766

Toner Chip (For Metered Machine):

106R03733 106R03736 106R03735 106R03734

Drum Chip:

113R00780 113R00782

Share this post



← Older Post Newer Post →


2 comments

  • 061-371 Communication error between ESS and magenta LPH (error in the communication IC or cable). It may occur due to an external noise, poor connection of FFC, poor power supply, etc.

    If you can’t fix this error, I think you need to ask help from local technician.

    XwkTech on
  • I am unable to fix Error code 061-371.Please help solve this issue I’m having.Looking forward to your reply.

    Muhammad Osama on