How to Fix 089-623 089-629 089-674 to 089-679 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

089-623, 629, 674, 676, 677, 679 MOB ADC Sensor Fail RAPBSD-ON: BSD 9.9 ADC and Environment Sensing089-623 The amount of reflected light was not stabilized during MOB ADC In Sensor LED brightness correction.089-629 The amount of reflected light was not stabilized during MOB ADC Out Sensor LED brightness correction.089-674 The LED light amount setting value does not converge in gain correction of the MOB ADC In Sensor LED Brightness Correction.089-676 The LED light amount setting value does not converge in gain correction of the MOB ADC Out Sensor LED Brightness Correction.089-677 An error occurs in the output voltage value of...

Read more →

How to Fix 089-617 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

089-617 RC Data Over Range RAP089-617 The result from adding the offset value to the correction value has exceeded the settable range.Initial ActionsEnter dC125, if multiple chain 89 faults are indicated, refer to Chain 089 Entry RAP to determine the highest priority fault.ProcedureEnter dC131, check the NVM values that follow:• 759-319 (Lead Registration Offset).• 759-321 (Side 1 Registration Offset).• 759-322 (Side 2 Registration Offset).**This RAP is from Xerox Service Manual. All brand names and trademarks are their respective owner's property.**You may be also interested in below toner and drum chip (CRUM) for Xerox VersaLink C7020, C7025, C7030, C7000.Toner Chip (For...

Read more →

How to Fix 089-616 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

089-616 RC Data Overflow Fail-B RAP089-616 The correction setting value of the calculation result has exceeded the allowed range.Initial ActionsEnter dC125, if multiple chain 89 faults are indicated, refer to Chain 089 Entry RAP to determine the highest priority fault.ProcedureWARNING: Ensure that the electricity to the machine is switched off while performing tasks that do not need electricity. Refer to GP 10. Disconnect the power cord. Electricity can cause death or injury. Moving parts can cause injury.Enter dC675, perform the registration control setup cycle and compare the correction amount with the value in Table 1. Table 1 Registration control adjustment...

Read more →

How to Fix 089-604 to 089-615 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

089-604, 606, 607, 609, 610, 612, 613, 615 RC Sample Block Fail-B RAPBSD-ON: BSD 9.9 ADC and Environment Sensing, BSD 9.4 Development (1 of 2).089-604 During the yellow B (rough adjustment pattern) patch detection, the patch at the MOB ADC In Sensor did not satisfy the defined number of valid sample blocks.089-606 During the yellow B (rough adjustment pattern) patch detection, the patch at the MOB ADC Out Sensor did not satisfy the defined number of valid sample blocks.089-607 During the magenta B (rough adjustment pattern) patch detection, the patch at the MOB ADC In Sensor did not satisfy the...

Read more →

How to Fix 089-601 089-603 Error Code for Xerox VersaLink C7020 C7025 C7030 C7000 Printer?

Posted by Xwk Tech on

089-601, 089-603 RC Sample Block Fail-A1 RAPBSD-ON: BSD 9.9 ADC and Environment Sensing.089-601 During the A1 (fine adjustment pattern) and C patch detection, the patch at the MOB ADC Sensor In did not satisfy the defined number of valid sample blocks.089-603 During the A1 (fine adjustment pattern) and C patch detection, the patch at the MOB ADC Sensor Out did not satisfy the defined number of valid sample blocks.Initial ActionsEnter dC125, if multiple chain 89 faults are indicated, refer to Chain 089 Entry RAP to determine the highest priority fault.ProcedureWARNING: Ensure that the electricity to the machine is switched off...